Flow switch
AS-0910
A stock
@
The best for "Flow or Non-flow" checks such as cooling water, hot water and lubricating oil

Dimensions and Materials


connection@Lmm
@Rc3/8@85
@Rc1/2@100
@Rc3/4@100

1.Body
SUS304
2.Float
SUS304
3.stopper
SUS316
4.Slider(Terminal Box)@
Polyacetal

AS-0910 works based on the principle of variable area flow meter.
As flow increases or decreases, afloat equipped with a magnet inside the units actuates or deactivates reed switch at the setpoint.

Function & Specifcation

Size@*1
10A
15A
20A
Flow Setting Ranges(Water)
0.6`4
l/min
0.5`6
l/min
1`11
l/min
Max Operating Pressure
30MPa
15MPa
12MPa
Max Operating Temperature
80Ž
Mounting
(Flow Direction)
Vertical(bottom to top)
Accuracy
Set Point Accuracy :
}5“@FS
Repeatability :
}2“@FS
Contact Type
SPST,Normally Open at No Flow *2
ON-OFF Differential : 15% FS
Switch Type
Reed Switch (self-hold)
Contact Rating
Voltage
220V
AC/DC Max.
Current
0.5A
Max.
Capacity
50VA
Max.
Contact Resistance
Less than 400mƒΆ
Terminal Box
A drip-proof type
Mass(g)
300
300
310
*1@The flow setting ranges are for the use with water. For the use with oil or other height viscosity liquid,please see conversion curves.
*2@When you want to change the contact type to "Normally Closed at No Flow",you can do so by changing the position of "switch unit" inside the terminal box (See "Switch ON/OFF Direction Change" in manual)
click here for the drawings.