Sight glass type Flow indicator
FS-0400
2 weeks leadtime
 
"OK" for gas
Specification
1.Accuracy ±5%F.S.
2.Range abilty 10:2
3.Temperature MAX.120℃
4.Pressure
15mm-125mm
150mm
200mm
250mm-300mm
1.0MPa
0.8MPa
0.6MPa
0.5MPa
5.Connection RC1/2,3/4 Screwed
More than 25mm Flanged
6.Material
Body Less than 100mm FC200
More than 125mm SS400
Parts SUS304 (flapper,spring,shaft)
sight glass   Temperd glass

Selection range of the maximum scale
Size(mm) Water Air
RC1/2(15)
RC3/4(20)
0.6-2m3/h
0.6-2
20-65m3/h(ntp)
20-65
Flanged 25 
32 
40 
50 
65 
80 
100 
1.2-5
1.2-5
2-10
3-15
8-36
12-50
20-90
40-160
40-160
70-330
100-500
270-1,100
400-1,600
700-3,000
125 
150 
200 
250 
300 
20-150
36-200
60-460
150-500
200-600
700-5,000
1,200-6,500
2,000-15,000
5,000-16,000
7,000-20,000
Choose maximum scale (good step numerical value) from the above range. The air flow rate is measured under the operating condition of 20deg.C. and 50kPa.